Publication Details

AFRICAN RESEARCH NEXUS

SHINING A SPOTLIGHT ON AFRICAN RESEARCH

chemistry

Fluorine speciation analysis using reverse phase liquid chromatography coupled off-line to continuum source molecular absorption spectrometry (CS-MAS): Identification and quantification of novel fluorinated organic compounds in environmental and biological samples

Analytical Chemistry, Volume 84, No. 14, Year 2012

Figure Persented: Driven by increasing demand for the monitoring of industrial perfluorinated compounds (PFCs), the identification of novel fluorine containing compounds (FOCs) and the tracking of organofluorine drugs and their degradation products, there is a clear need for sensitive, fluorine-specific detection of unknown FOCs. Here we report the first ever direct fluorine-specific (speciation) method; capable of individually detecting untargeted FOCs in environmental and biological samples through the application of continuum source molecular absorption spectrometry (CS-MAS) using a commercial CS-AAS. Two model FOCs (2,4,6, trifluorobenzoic acid (TFBA) and 5-fluoroindol-5-carboxylic acid (FICA)) were used, achieving fluorine-specific detection across a range of 0.1 to 300 ng/mL fluorine, corresponding to a limit of detection of 4 pg F and 5.26 nM for both compounds. Both TFBA and FICA showed a similar response to CS-MAS detection, potentially enabling the quantification of fluorine content in novel FOCs without having molecular standards available. This paper also reports the use of reverse-phase high performance liquid chromatography (RP-HPLC) coupled off-line with CS-MAS for the identification of single organofluorines in a mixture of FOCs via fraction collection. The linear range of both FOCs was determined to be from 1 to 500 ng/mL. The limits of detection of those species were just above 1 ng/mL (100 pg) and can therefore compete with targeted analytical methods such as ESI-MS. Finally, as a proof of principle the analysis of a fluoride-containing groundwater sample from Ghana demonstrated that this method can be used in the detection of novel FOCs, with identification achieved through parallel ESI-MS. Coupled HPLC-CS-MAS/ESI-MS is the first analytical methodology capable of selectively detecting and identifying novel FOCs, making possible the quantification of all fluorine containing compounds in one sample. This is the necessary analytical requirement to perform fluoronomics. © 2012 American Chemical Society.

Statistics
Citations: 46
Authors: 9
Affiliations: 3
Identifiers
Study Locations
Ghana