Skip to content
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Menu
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Menu
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Publication Details
AFRICAN RESEARCH NEXUS
SHINING A SPOTLIGHT ON AFRICAN RESEARCH
biochemistry, genetics and molecular biology
[
18
FDG] PET-CT-Based Intensity-Modulated Radiotherapy Treatment Planning of Head and Neck Cancer
International Journal of Radiation Oncology Biology Physics, Volume 69, No. 1, Year 2007
Notification
URL copied to clipboard!
Description
Purpose: To define the best threshold for tumor volume delineation of the (18) fluoro-2-deoxy-glucose positron emission tomography (18FDG-PET) signal for radiotherapy treatment planning of intensity-modulated radiotherapy (IMRT) in head and neck cancer. Methods and Materials: In 25 patients with head-and-neck cancer, CT-based gross tumor volume (GTVCT) was delineated. After PET-CT image fusion, window level (L) was adapted to best fit the GTVCT, and GTVPET was delineated. Tumor maximum (S) and background uptake (B) were measured, and the threshold of the background-subtracted tumor maximum uptake (THR) was used for PET signal segmentation. Gross tumor volumes were expanded to planning target volumes (PTVs) and analyzed. Results: The mean value of S was 40 kBq/mL, S/B ratio was 16, and THR was 26%. The THR correlated with S (r = -0.752), but no correlation between THR and the S/B ratio was seen (r = -0.382). In 77% of cases, S was >30 kBq/mL, and in 23% it was ≤30 kBq/mL, with a mean THR of 21.4% and 41.6%, respectively (p < 0.001). Using PTVPET in radiotherapy treatment planning resulted in a reduced PTV in 72% of cases, while covering 88.2% of GTVCT, comparable to the percentage of GTVPET covered by PTVCT (p = 0.15). Conclusions: A case-specific PET signal threshold is optimal in PET-based radiotherapy treatment planning. Signal gating using a THR of 20% in tumors with S >30% ± 1.6% kBq/mL and 40% in tumors with S ≤30% ± 1.6% kBq/mL is suitable. © 2007 Elsevier Inc. All rights reserved.
Authors & Co-Authors
El-Bassiouni, Mazen
Unknown Affiliation
Ciernik, Ilja Frank
Switzerland, Bellinzona
Ospedale San Giovanni
Davis, J. Bernard
Unknown Affiliation
el-Attar, Inas A.
Egypt, Giza
Cairo University
Reiner, Beatrice
Unknown Affiliation
Burger, Cyrill
Switzerland, Zurich
Universitatsspital Zurich
Goerres, Gerhard W.
Switzerland, Zurich
Universitatsspital Zurich
Studer, Gabriela M.
Unknown Affiliation
Statistics
Citations: 46
Authors: 8
Affiliations: 4
Identifiers
Doi:
10.1016/j.ijrobp.2007.04.053
ISSN:
03603016
Research Areas
Cancer
Environmental