Skip to content
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Menu
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Menu
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Publication Details
AFRICAN RESEARCH NEXUS
SHINING A SPOTLIGHT ON AFRICAN RESEARCH
medicine
Balloon mitral valvotomy with a single catheter: A comparison between bifoil/trefoil and the inoue balloon
European Heart Journal, Volume 14, No. 8, Year 1993
Notification
URL copied to clipboard!
Description
Results of percutaneous mitral valvotomy were compared in two groups undergoing the procedure at our institution. Group I: 100 patients having had percutaneous valvotomy with the Schneider-Medintag bifoil (2 × 19 mm) or trefoil (3 × 15 mm or 3 × 12 mm) catheters, and group II: 150 patients in whom the procedure was performed with the Inoue balloon (24-30 mm). Baseline clinical (age, gender, NYHA class and echo score) and haemodynamic variables were similar in both groups.Haemodynamic improvement occurred in both groups. Although the reduction in left atrial pressure did not differ significantly between the two groups, the increase in mitral valve area was significantly (P<0.001) higher for group I (0.8±0.2 to 1.9±0.7 and 0.8±0.3 to 1.6±0.3 cm2 respectively for mitral area, and 22±6 to 13±5 and 21±6 to 13±5 mmHg respectively for mean left a trial pressure). The increase in cardiac output was statistically significant in group I (3.2±0.7 to 4.0±0.91. min-1, P<0.05) but not in group II (3.5±2.0 to 3.7±0.91. min-1, ns).Inter-atrial shunting immediately after valvotomy was recorded in 19% of group I patients compared with 6% in group II (P<0.01). The overall incidence of significant mitral regurgitation (3+ or 4+) was similar in both groups (5% and 4% respectively). However, when the stepwise dilatation technique was employed in group II, the incidence had dropped to 2.1%.The total procedure time was significantly lower in group II (80±13 vs 102±10 min in group I P<0.01), and the technical success rate was 96% in group Iand 100% in group II. Four patients from group I, in whom there was technical dfficulty in positioning the balloon across the mitral valve, had a successful outcome with the Inoue balloon when the procedure was repeated.It is concluded that the Inoue and bifoil/trefoil balloon produce equivalent haemodynamics, but the Inoue technique is simpler and takes less time to perform. The larger increase in cardiac output after valvotomy and hence the larger mitral valve area in the bifoil/trefoil group is probably the result of the significantly higher incidence of left to right atrial shunting in this group. © 1993 The Europen Society of Cardiology.
Authors & Co-Authors
Patel, Jai J.B.
South Africa, Durban
University of Kwazulu-natal
Mitha, Abdul S.
South Africa, Durban
University of Kwazulu-natal
Chetty, Sivabakiyam
South Africa, Durban
University of Kwazulu-natal
Hung, Juisung
South Africa, Durban
University of Kwazulu-natal
Statistics
Citations: 6
Authors: 4
Affiliations: 1
Identifiers
Doi:
10.1093/eurheartj/14.8.1065
ISSN:
0195668X
Research Areas
Noncommunicable Diseases
Study Design
Cohort Study