Hot spots of NOx emission from the cement factory main stacks
Fresenius Environmental Bulletin, Volume 26, No. 12, Year 2017
Notification
URL copied to clipboard!
The aim of this study was to assess nitrogen oxides (NOx) dispersion from the main stacks of a cement factory in Doroud, Iran. The SCREEN3 software and Gaussian plume model were applied to predict and to compare the on-site NOx concentrations to provide relevant information on its emissions and dispersion. The results showed that within a radius of 400-650 m from the source, the estimated NOx concentrations were higher than the National Ambient Air Quality Standards for human health protection. Therefore, a distance higher than 650 m at downwind direction of the source was recommended for human settling and activities.