Publication Details

AFRICAN RESEARCH NEXUS

SHINING A SPOTLIGHT ON AFRICAN RESEARCH

medicine

Medtronic Freestyle aortic bioprosthesis: A potential option for haemodialysis patients

Interactive Cardiovascular and Thoracic Surgery, Volume 22, No. 4, Year 2016

OBJECTIVES End-stage renal disease patients on regular haemodialysis are at higher risk of calcification. Therefore, many surgeons have concerns regarding the implantation of bioprostheses in such patients. The haemodynamic advantages of stentless aortic bioprostheses support their use; however, these have not been studied yet in end-stage renal disease patients. We studied accordingly the early and mid-term outcomes of aortic valve replacement (AVR) using Medtronic Freestyle stentless aortic bioprostheses in this subset of patients in comparison with stented aortic bioprostheses. METHODS We retrospectively studied two groups of consecutive patients on regular haemodialysis who required AVR between 2007 and 2013. Non-Freestyle (NFS) group received stented aortic bioprostheses (36 patients) and Freestyle (FS) group received Medtronic Freestyle aortic bioprostheses (48 patients). Follow-up ranged from 2 to 76 months with a mean follow-up of 36.3 ± 25 months. RESULTS Patients in both groups showed similar demographic characters regarding age (76.4 ± 8.1 vs 74.9 ± 7.2 years; P = 0.35), male gender (58 vs 60%; P = 0.57) and diabetes mellitus (42 vs 48%; P = 0.57). Smaller aortic bioprostheses were implanted in the NFS (23.3 ± 1.2 vs 25.4 ± 2.1; P < 0.001) with consequently higher postoperative mean gradients (14.1 ± 4.1 vs 11.9 ± 5.3 mmHg; P = 0.004). No significant differences were noted regarding postoperative neurological disorder (8 vs 12%; P = 0.73), deep sternal wound infection (3 vs 4%; P = 0.68), re-exploration (8 vs 8%; P = 0.91) and in-hospital mortality (6 vs 4%; P = 0.92). Mid-term follow-up showed higher prosthetic valve calcification and/or sclerosis in NFS group (25 vs 6%; P = 0.015), whereas no significant differences were noticed between the two groups regarding stroke (0 vs 8%; P = 0.13), endocarditis (0 vs 4%; P = 0.50), 36- and 72-month survival (51 ± 2%, 14 ± 4% vs 55 ± 2%, 19 ± 3%, respectively; P = 0.45). CONCLUSIONS Aortic bioprostheses are a good option for haemodialysis patients requiring AVR, offering acceptable mid-term survival. The Medtronic Freestyle aortic bioprostheses could allow the implantation of larger bioprostheses inferring consequently lower mean gradients, with a potentially higher resistance to calcification and sclerosis in haemodialysis patients.
Statistics
Citations: 5
Authors: 5
Affiliations: 3
Identifiers
Research Areas
Health System And Policy
Noncommunicable Diseases
Study Design
Cohort Study
Participants Gender
Male