Skip to content
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Menu
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Menu
Home
About Us
Resources
Profiles Metrics
Authors Directory
Institutions Directory
Top Authors
Top Institutions
Top Sponsors
AI Digest
Contact Us
Publication Details
AFRICAN RESEARCH NEXUS
SHINING A SPOTLIGHT ON AFRICAN RESEARCH
medicine
Pelvic static magnetic stimulation to control urinary incontinence in older women: A randomized controlled trial
Clinical Medicine and Research, Volume 10, No. 1, Year 2012
Notification
URL copied to clipboard!
Description
Objectives To determine the efficacy of non-invasive static magnetic stimulation (SMS) of the pelvic floor compared to placebo in the treatment of women aged 60 years and over with urinary incontinence for 6 months or more. Subjects and Methods A single-blinded randomized, placebo-controlled, parallel-group trial. Subjects were excluded if they had an implanted electronic device, had experienced a symptomatic urinary tract infection, or had commenced pharmacotherapy for the same in the previous 4 weeks, or if they were booked for pelvic floor or gynecological surgery within the next 3 months. Once written consent was obtained, subjects were randomly assigned to the active SMS group (n=50) or the placebo group (n=51). Treatment was an undergarment incorporating 15 static magnets of 800-1200 Gauss anterior, posterior, and inferior to the pelvis for at least 12 hours a day for 3 months. Placebo was the same protocol with inert metal disks replacing the magnets. Primary outcome measure was cessation of incontinence as measured by a 24-hour pad test. Secondary outcomes were frequency and severity of symptoms as measured by the Bristol Female Lower Urinary Tract Symptoms questionnaire (BFLUTS-SF), the Incontinence Severity Index, a Bothersomeness Visual Analog scale, and a 24-hour bladder diary. Data were collected at baseline and 12 weeks later. Results There were no statistically significant differences between groups in any of the outcome measures from baseline to 12 weeks. Initial evidence of subjective improvement in the treatment group compared to the placebo group was not sustained with sensitivity analysis. Conclusion This study found no evidence that static magnets cure or decrease the symptoms of urinary incontinence. Additional work into the basic physics of the product and garment design is recommended prior to further clinical trials research. ©2012 Marshfield Clinic.
Authors & Co-Authors
Wallis, Marianne Clare
Australia, Brisbane
Griffith University
Australia, Southport
Gold Coast Health
Davies, Elizabeth A.
Australia, Brisbane
The University of Queensland
Thalib, Lukman
Kuwait, Kuwait City
Kuwait University
Griffiths, Susan
Australia, Brisbane
Griffith University
Statistics
Citations: 27
Authors: 4
Affiliations: 4
Identifiers
Doi:
10.3121/cmr.2011.1008
ISSN:
15394182
e-ISSN:
15546179
Research Areas
Health System And Policy
Study Approach
Quantitative
Participants Gender
Female