Publication Details
AFRICAN RESEARCH NEXUS
SHINING A SPOTLIGHT ON AFRICAN RESEARCH
medicine
Five-year clinical outcome of titanium-nitride-oxide-coated bioactive stent implantation in a real-world population: A comparison with paclitaxel-eluting stents: The pori registry
Journal of Interventional Cardiology, Volume 24, No. 1, Year 2011
Notification
URL copied to clipboard!
Description
Aims: We sought to present the 5-year clinical outcome of the titanium-nitride-oxide-coated bioactive stents (BAS), as compared to paclitaxel-eluting stents (PES), in a real-world patient population. Methods: From May 2003 to November 2004, we enrolled 405 consecutive patients who underwent percutaneous coronary intervention with either BAS or PES implantation. Patients were prospectively followed up for 5 years. The primary end-point was major adverse cardiac events (MACE) at 5-year follow-up including cardiac death, nonfatal myocardial infarction (MI), or target lesion revascularization. Results: A total of 201 patients received BAS (218 lesions/221 stents) while 204 patients received PES (244 lesions/247 stents). Clinical follow-up for 5 years was completed in all patients. Cumulative MACE at the end of 5-year follow-up occurred in 34 (16.9%) patients in the BAS group, as compared to 53 (26%) in the PES group (OR 1.7, 95% CI 1.1-2.8, P = 0.03). This difference was mainly driven by a lower incidence of MI in the BAS group as compared with the PES group (9.5% vs. 20.6%, OR 2.5, 95% CI 1.4-4.4, P = 0.002). Stent thrombosis occurred in 16 (7.8%) patients in the PES group, while no one suffered stent thrombosis in the BAS group. Conclusion: BAS implantation in a real-world patient population achieves an excellent clinical outcome over 5-year follow-up, with a significantly lower incidence of MI, MACE, and stent thrombosis as compared to PES. © 2010, Wiley Periodicals, Inc.
Authors & Co-Authors
Karjalainen, Pasi Paavo
Finland, Pori
Satakunta Central Hospital
Ylitalo, Antti S.
Finland, Pori
Satakunta Central Hospital
Airaksinen, Juhani K.E.
Finland, Turku
Turun Yliopistollinen Keskussairaala
Nammas, Wail M.
Egypt, Cairo
Ain Shams University Hospitals
Statistics
Citations: 37
Authors: 4
Affiliations: 3
Identifiers
Doi:
10.1111/j.1540-8183.2010.00601.x
ISSN:
08964327
e-ISSN:
15408183
Research Areas
Health System And Policy
Noncommunicable Diseases
Study Design
Randomised Control Trial
Cross Sectional Study
Cohort Study